Concordancia entre la aplicación Clinometer® y el goniómetro para la medición de la flexión dorsal de tobillo en sujetos sanos

Autores/as

  • Camila Litardo Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • María Agustina Ametrano Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Gisela Aquino Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Ramiro Bragagnolo Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Adrián Orlando Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Camila Melisa Patrinós Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Marcelino Moris Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Sebastián Ariel Barreiro González Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Karen Anabella Molina Hospital Zonal General de Agudos Mariano y Luciano de La Vega
  • Erika Riabtschenko Hospital Zonal General de Agudos Mariano y Luciano de La Vega

DOI:

https://doi.org/10.58172/ajrpt.v3i2.118

Palabras clave:

Clinometer®, goniómetro, rango de movimiento, tobillo, dorsiflexión, estudio de concordancia

Resumen

Objetivo: Determinar el nivel de concordancia entre el Clinometer® y el goniómetro universal (GU) para la medición de la dorsiflexión de tobillo sin carga de peso en sujetos sanos.

Materiales y método: Se utilizó un diseño descriptivo y transversal con medidas simultáneas con evaluadores ciegos. Se realizó un muestreo por conveniencia. Se incluyeron sujetos de ambos sexos mayores de 18 años que concurrieron al consultorio externo de la unidad de kinesiología del Hospital Zonal General de Agudos Mariano y Luciano de la Vega. 

Resultados: Se incluyeron 87 sujetos, de los cuales 60 (69,5%) fueron de sexo femenino. Presentaron una media de edad de 39 años (desvío estándar de 10). El Coeficiente de Correlación Intraclase (CCI) fue de 0,93 (intervalo de confianza del 95%, 0,86 a 0,95), siendo adecuado según la guía de COSMIN. La correlación entre ambos métodos fue alta y significativa (p< 0,05).

Conclusión: En el presente estudio se ha analizado la concordancia del Clinometer® y el GU en sujetos sanos para medir la flexión dorsal de tobillo sin carga de peso. La aplicación es una alternativa sencilla y económica para medir el rango de movilidad, que permite objetivar la evolución del paciente.

Descargas

Los datos de descargas todavía no están disponibles.

Citas

Green S, Buchbinder R, Glazier R, Forbes A. Systematic review of randomised controlled trials of interventions for painful shoulder: selection criteria, outcome assessment, and efficacy. BMJ. 1998 Jan 31;316(7128):354-60.

Protopapadaki A, Drechsler WI, Cramp MC, Coutts FJ, Scott OM. Hip, knee, ankle kinematics and kinetics during stair ascent and descent in healthy young individuals. Clin Biomech. 2007 feb;22(2):203-10.

Bell-Jenje T, Olivier B, Wood W, Rogers S, Green A, McKinon W. The association between loss of ankle dorsiflexion range of movement, and hip adduction and internal rotation during a step down test. Man Ther. 2016 Feb;21:256-61.

Joseph M, Tiberio D, Baird JL, Trojian TH, Anderson JM, Kraemer WJ, Maresh CM. Knee valgus during drop jumps in National Collegiate Athletic Association Division I female athletes: the effect of a medial post. Am J Sports Med. 2008 Feb;36(2):285-9.

Gross MT. Lower quarter screening for skeletal malalignment--suggestions for orthotics and shoewear. J Orthop Sports Phys Ther. 1995 Jun;21(6):389-405.

Powers CM. The influence of altered lower-extremity kinematics on patellofemoral joint dysfunction: a theoretical perspective. J Orthop Sports Phys Ther. 2003 Nov;33(11):639-46.

Sigward SM, Ota S, Powers CM. Predictors of frontal plane knee excursion during a drop land in young female soccer players. J Orthop Sports Phys Ther. 2008 Nov;38(11):661-667.

Rabin A, Kozol Z, Spitzer E, Finestone A. Ankle dorsiflexion among healthy men with different qualities of lower extremity movement. J Athl Train. 2014 Sep-Oct;49(5):617-23.

Bell DR, Padua DA, Clark MA. Muscle strength and flexibility characteristics of people displaying excessive medial knee displacement. Arch Phys Med Rehabil. 2008 Jul;89(7):1323-8.

Fong CM, Blackburn JT, Norcross MF, McGrath M, Padua DA. Ankle-dorsiflexion range of motion and landing biomechanics. J Athl Train. 2011 Jan-Feb;46(1):5-10.

Piva SR, Goodnite EA, Childs JD. Strength around the hip and flexibility of soft tissues in individuals with and without patellofemoral pain syndrome. J Orthop Sports Phys Ther. 2005 Dec;35(12):793-801.

Alawna MA, Unver BH, Yuksel EO. The Reliability of a Smartphone Goniometer Application Compared With a Traditional Goniometer for Measuring Ankle Joint Range of Motion. J Am Podiatr Med Assoc. 2019 Jan;109(1):22-29.

Norkin CC, White DJ. Measurement of Joint Motion: A Guide to Goniometry. Philadelphia: FA Davis Company. 2006. 3ra Edición.

Mourcou Q, Fleury A, Diot B, Franco C, Vuillerme N. Mobile Phone-Based JointAngle Measurement for Functional Assessment and Rehabilitation of Proprioception. Biomed Res Int. 2015;2015: 328142.

Munteanu SE, Strawhorn AB, Landorf KB, Bird AR, Murley GS. A weightbearing technique for the measurement of ankle joint dorsiflexion with the knee extended is reliable. J Sci Med Sport. 2009 Jan;12(1):54-9.

Werner BC, Holzgrefe RE, Griffin JW, Lyons ML, Cosgrove CT, Hart JM, Brockmeier SF. Validation of an innovative method of shoulder range-of-motion measurement using a smartphone clinometer application. J Shoulder Elbow Surg. 2014 nov, 1-8.

Shin SH, Ro du H, Lee OS, Oh JH, Kim SH. Within-day reliability of shoulder range of motion measurement with a smartphone. Man Ther. 2012 Aug;17(4).

Cox RW, Martinez RE, Baker RT, Warren L. Validity of a Smartphone Application for Measuring Ankle Plantar Flexion. J Sport Rehabil. 2018 May 1;27(3).

Cosby NL, Hertel J. Relationships between measures of posterior talar glide and ankle dorsiflexion range of motion. Athletic Training & Sports Health Care.2011; 3(2)

Mokkink LB, Terwee CB, Patrick DL, et al. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Qual Life Res. 2010;19:539-549.

Konor MM, Morton S, Eckerson JM, Grindstaff TL. Reliability of three measures of ankle dorsiflexion range of motion. Int J Sports Phys Ther. 2012 jun;7(3).

Venturini C, Ituassú NT, Teixeira LM, Deus CVO. Confiabilidade intra e interexaminadores de dois métodos de medida da amplitude ativa de dorsiflexao do tornozeloem indivíduos saudáveis. Rev. bras. Fisioter. 2006. 10(4): 407:411.

Archivos adicionales

Publicado

2021-07-01

Cómo citar

Litardo, C., Ametrano, M. A., Aquino, G., Bragagnolo, R., Orlando, A., Patrinós, C. M., … Riabtschenko, E. (2021). Concordancia entre la aplicación Clinometer® y el goniómetro para la medición de la flexión dorsal de tobillo en sujetos sanos. Argentinian Journal of Respiratory & Physical Therapy, 3(2), 31–36. https://doi.org/10.58172/ajrpt.v3i2.118